@@ -0,0 +1,74 @@
# Agent Note: Win32 dialog worker source launch drops the tsx bootstrap

Status: implemented

English | [中文](2026-08-19-win32-dialog-worker-source-launch.zh.md)

## Problem

On Windows, the source-plane folder dialog worker never started: the Web UI
reported `win32 folder dialog worker exited before reporting a result`. The
root cause is the launch vector, not koffi: `spawnDialogWorker`'s source arm
ran `node --import tsx/esm <absolute .ts path>`. With a loader registered via
`--import`, Node's ESM loader resolves the entry as a URL, and a Windows
absolute path (`E:\...`) becomes an `e:` scheme URL, throwing
`ERR_UNSUPPORTED_ESM_URL_SCHEME` before the worker's first IPC message. The
driver then surfaces only its generic exit error. Packaged consumers were
unaffected because they launch the built `worker.cjs` under plain node; the
bug hit every source launch (`pnpm dsh web`) on Windows.

CI missed it for a second, compounding reason: the built/source arm choice
tested `import.meta.url.endsWith('.ts')`, and under Vitest/Vite the URL carries
a query string (`?v=...`), so the win32 smoke test silently exercised the built
arm — never the broken source launch.

## Decision

Run the source worker under plain node with native type stripping, no tsx
bootstrap:

```ts
spawn(process.execPath, [fileURLToPath(new URL('./win32-dialog-worker.ts', import.meta.url))], ...)
```

This is safe because the worker's dependency chain (worker, bindings, logic)
uses only erasable TypeScript syntax — no parameter properties, decorators, or
value namespaces — unlike the CLI source graph that keeps the tsx ESM hook.
Native type stripping is stable since Node 22.18, inside the engines range
(`^22.19.0 || >=24.0.0`). The built arm (`worker.cjs` under plain node) is
unchanged.

The arm choice now reads `new URL(import.meta.url).pathname.endsWith('.ts')` so
bundler query strings cannot misclassify source modules as built. This makes
the win32 smoke test exercise the real source launch, and the new
`win32-dialog-host.spec.ts` case pins that the source arm passes the worker
path positionally with no `--import` flag.

## Alternatives considered

**Pass the worker as a `file://` URL instead of a path.** Rejected: tsx's
tsconfig-paths hook mangles `file://` URLs into `<cwd>\file:\<path>`
(`ERR_MODULE_NOT_FOUND`); keeping any tsx involvement leaves a fragile launch.

**Probe koffi availability and fall back to pure-Node dialogs.** Out of scope:
dshcode pins koffi 3.1.1, which predates the broken 3.1.3/3.1.4 win32-x64
prebuilds, so the worker's koffi usage is not the failure on this codebase; the
worker itself crashed before koffi ever loaded.

## Consequences

- Windows source launches (`pnpm dsh web`) open the folder dialog again; the
failure mode (`e:` scheme URL) is gone with the loader chain.
- No functional change for packaged hosts or POSIX: they already ran the worker
under plain node.
- The win32 smoke test now covers the source arm end to end; a regression to a
loader-bootstrapped launch is caught by both the spawn-args pin and the real
dialog smoke.

## Verification

`packages/host/directory-picker-native/tests/win32-dialog.spec.ts` opens and
abort-closes a real dialog through the source launch. The new
`win32-dialog-host.spec.ts` case asserts the positional worker path with no
`--import`. Full package suite: 48 passed, 1 skipped (the win32-skipped
built-worker e2e).
Original file line number Diff line number Diff line change
@@ -0,0 +1,63 @@
# Agent Note: Win32 对话框 worker 源码启动去掉 tsx 引导

Status: implemented

[English](2026-08-19-win32-dialog-worker-source-launch.md) | 中文

## 问题

在 Windows 上,源码层面的文件夹对话框 worker 从未成功启动:Web UI 报
`win32 folder dialog worker exited before reporting a result`。根因在启动方式而非
koffi:`spawnDialogWorker` 的源码分支以 `node --import tsx/esm <绝对路径 .ts>`
运行。通过 `--import` 注册 loader 后,Node 的 ESM loader 会把入口当作 URL
解析,Windows 绝对路径(`E:\...`)变成 `e:` 协议 URL,在 worker 发出第一条
IPC 消息之前就抛出 `ERR_UNSUPPORTED_ESM_URL_SCHEME`。驱动端于是只上报笼统的
退出错误。打包用户不受影响,因为他们以纯 node 启动构建产物 `worker.cjs`;
该 bug 命中 Windows 上每一次源码启动(`pnpm dsh web`)。

CI 漏掉它还有第二个叠加原因:built/源码分支选择用的是
`import.meta.url.endsWith('.ts')`,而在 Vitest/Vite 下 URL 带查询串(`?v=...`),
win32 冒烟测试静默地走了 built 分支——从未覆盖坏掉的源码启动。

## 决策

源码 worker 以纯 node + 原生类型剥离运行,不再经过 tsx 引导:

```ts
spawn(process.execPath, [fileURLToPath(new URL('./win32-dialog-worker.ts', import.meta.url))], ...)
```

这是安全的,因为 worker 的依赖链(worker、bindings、logic)只用可擦除的
TypeScript 语法——没有参数属性、装饰器或值命名空间——不像保留 tsx ESM
hook 的 CLI 源码图。原生类型剥离自 Node 22.18 起稳定,落在 engines 范围
(`^22.19.0 || >=24.0.0`)内。built 分支(纯 node 跑 `worker.cjs`)不变。

分支选择改为 `new URL(import.meta.url).pathname.endsWith('.ts')`,bundler
查询串无法再把源码模块误判为 built 产物。这让 win32 冒烟测试真正覆盖源码
启动;新增的 `win32-dialog-host.spec.ts` 用例固定源码分支以位置参数传入
worker 路径且不带 `--import`。

## 考虑过的备选方案

**把 worker 作为 `file://` URL 而非路径传入。**拒绝:tsx 的 tsconfig-paths
钩子会把 `file://` URL 破坏成 `<cwd>\file:\<path>`
(`ERR_MODULE_NOT_FOUND`);只要还沾 tsx,启动就是脆弱的。

**探测 koffi 可用性并回退到纯 Node 对话框。**超出范围:dshcode 固定
koffi 3.1.1,早于损坏的 3.1.3/3.1.4 win32-x64 预编译,worker 的 koffi 用法
在本代码库并非故障点;worker 在 koffi 加载之前就已崩溃。

## 影响

- Windows 源码启动(`pnpm dsh web`)重新能弹出文件夹对话框;`e:` 协议
URL 这一失败模式随 loader 链一起消失。
- 打包宿主与 POSIX 无功能变化:它们本来就在纯 node 下运行 worker。
- win32 冒烟测试现在端到端覆盖源码分支;回归到 loader 引导启动会同时被
spawn 参数固定与真实对话框冒烟测试抓住。

## 验证

`packages/host/directory-picker-native/tests/win32-dialog.spec.ts` 通过源码
启动真实打开并中止关闭对话框。新增的 `win32-dialog-host.spec.ts` 用例断言
位置参数的 worker 路径且不带 `--import`。包内完整测试套件:48 通过,
1 跳过(win32 跳过的 built-worker e2e)。
3 changes: 1 addition & 2 deletions packages/host/directory-picker-native/package.json
Original file line number Diff line number Diff line change
Expand Up @@ -47,7 +47,6 @@
},
"devDependencies": {
"@deepseek-ai/dsh-invariants": "workspace:^",
"@deepseek-ai/cordis": "workspace:^",
"tsx": "^4.19.2"
"@deepseek-ai/cordis": "workspace:^"
}
}
17 changes: 12 additions & 5 deletions packages/host/directory-picker-native/src/win32-dialog-host.ts
Original file line number Diff line number Diff line change
Expand Up @@ -14,9 +14,10 @@ import type { Win32DialogWorkerData } from './win32-dialog-worker.ts'
/**
* Spawn the dialog child process. Built consumers launch the bundled CJS
* entry next to this module under plain node; unbuilt (source) consumers
* bootstrap tsx first, mirroring the dsh CLI's source launch. The dialog is
* the child's first window, so Windows activates it without a foreground
* call.
* run the worker directly under Node's native type stripping (stable since
* 22.18, covered by the engines range) — the worker's three modules use
* only erasable TS syntax, so no tsx bootstrap is needed. The dialog is the
* child's first window, so Windows activates it without a foreground call.
* @param data - the child payload (dialog title).
* @returns the spawned child process.
*/
Expand All @@ -25,11 +26,17 @@ export function spawnDialogWorker(data: Win32DialogWorkerData): ReturnType<typeo
// child-only Node mode bypasses application startup and its single-instance lock.
const env = { ...process.env, DSH_DIALOG_TITLE: data.title, ELECTRON_RUN_AS_NODE: '1' }
const stdio: StdioOptions = ['ignore', 'inherit', 'inherit', 'ipc']
// Pathname (not the raw URL): bundlers/tests append query strings (?v=...) to
// the URL, which would misclassify source modules as built and silently test
// the wrong arm. The pathname ends with .ts only for the unbuilt source plane.
/* v8 ignore next 3 -- the built-output arm: tests always run unbuilt (src/) */
if (!import.meta.url.endsWith('.ts')) {
if (!new URL(import.meta.url).pathname.endsWith('.ts')) {
return spawn(process.execPath, [fileURLToPath(new URL('./worker.cjs', import.meta.url))], { env, stdio, windowsHide: true })
}
return spawn(process.execPath, ['--import', import.meta.resolve('tsx/esm'), fileURLToPath(new URL('./win32-dialog-worker.ts', import.meta.url))], { env, stdio, windowsHide: true })
// `node <absolute .ts path>`: Node's ESM loader accepts a file path here (no
// tsx hook in front of it), so the absolute Windows path cannot be misparsed
// as an `e:` scheme URL — the failure mode when tsx's loader chain is active.
return spawn(process.execPath, [fileURLToPath(new URL('./win32-dialog-worker.ts', import.meta.url))], { env, stdio, windowsHide: true })
}

export { closeThreadWindows } from './win32-dialog-bindings.ts'
Original file line number Diff line number Diff line change
@@ -1,4 +1,5 @@
import type { ChildProcess, SpawnOptions } from 'node:child_process'
import { fileURLToPath } from 'node:url'
import { afterEach, beforeEach, describe, expect, it, vi } from 'vitest'

type SpawnWorker = (command: string, args: readonly string[], options: SpawnOptions) => ChildProcess
Expand Down Expand Up @@ -39,4 +40,16 @@ describe('spawnDialogWorker', () => {
})
expect(process.env.ELECTRON_RUN_AS_NODE).toBe('')
})

// Regression guard for the source plane: the worker must launch under plain
// node with native type stripping (no tsx bootstrap), so the absolute Windows
// path is a positional file argument, not a URL through a loader chain.
it('launches the source worker under plain node with no loader flags', () => {
spawnDialogWorker({ title: 'Source-plane guard' })

expect(spawnMock).toHaveBeenCalledOnce()
const args = spawnMock.mock.calls[0]?.[1]
expect(args).toEqual([fileURLToPath(new URL('../src/win32-dialog-worker.ts', import.meta.url))])
expect(args).not.toContain('--import')
})
})
Original file line number Diff line number Diff line change
Expand Up @@ -145,8 +145,9 @@ describe('pickWin32Directory', () => {
expect(close.mock.calls.length).toBeGreaterThan(10)
})

// POSIX hosts exercise the REAL default plumbing end to end: the tsx-bootstrapped
// worker spawns, loads koffi, fails to load ole32.dll, and reports the error.
// POSIX hosts exercise the REAL default plumbing end to end: the source
// worker spawns under plain node with native type stripping (no tsx
// bootstrap), loads koffi, fails to load ole32.dll, and reports the error.
it.skipIf(process.platform === 'win32')('rejects through the real worker where the Win32 surface is unavailable', async () => {
await expect(pickWin32Directory(live())).rejects.toThrow('win32 folder dialog failed')
}, 30_000)
Expand Down
3 changes: 0 additions & 3 deletions pnpm-lock.yaml

Some generated files are not rendered by default. Learn more about how customized files appear on GitHub.

Loading