Local-first Home Assistant integration for the Intex SX2100 WiFi sand
filter pump (Tuya AGP SAND FILTER PUMP R1, category rs, product
ff6aa9iqer5r7wtg). Purpose-built for this pump, with every datapoint
verified against real hardware.
- Features
- Installation
- Configuration
- Entities
- Schedules
- Automations
- Dashboard card
- Protocol reference
- Comparison with
Hovborg/intex-pool - Credits
- License
- Local control over your LAN via tinytuya (Tuya protocol 3.5) — switching and status work with no cloud dependency
- Full schedule management of the pump's 7 internal timer slots: enable/disable, start time, duration and repeat days, editable from the UI
- FP mode: start a one-time long filtration run (up to 48 h) with one button press — ideal after shock treatment or for cloudy water
- Maintenance monitoring: alarm codes (
E93,DIRTY, …), decoded error bitmap, runtime counter, and aproblemsensor ready for notification automations - HACS-ready with automated releases, hassfest/HACS CI, and built-in diagnostics export
HACS (recommended)
- HACS → three-dot menu → Custom repositories
- Add
https://github.com/thomasgregg/intex-ha(type Integration) - Install Intex SX2100 Pool Pump and restart Home Assistant
Manual
Copy custom_components/intex_sx2100 into your config/custom_components/
directory and restart.
Then add it under Settings → Devices & Services → Add Integration → Intex SX2100 Pool Pump.
| Setting | Required | Notes |
|---|---|---|
| IP address | ✅ | e.g. 192.168.178.146 — give the pump a static DHCP lease |
| Device ID | ✅ | from the Tuya wizard (below) |
| Local key | ✅ | from the Tuya wizard; rotates if the pump is re-paired in the app |
| Tuya cloud client ID + secret | optional | from iot.tuya.com, enables schedule entities |
| Cloud region | optional | data center of your app account, e.g. eu |
Schedules live only in the Tuya cloud (skdl_filter), so the cloud
credentials unlock them; switching and sensors are pure LAN either way.
Polling intervals are adjustable via the integration's Configure dialog
(defaults: local 15 s, cloud 15 min — well within Tuya's free API tier).
The pump talks on the LAN using a per-device local key. Tuya doesn't
show it in the app, so you retrieve it once via a free Tuya developer
account and the tinytuya wizard. You only do this once (the key stays
valid unless you re-pair the pump in the app).
1. Pair the pump in the Intex / Smart Life app (if you haven't already), and confirm it works there.
2. Create a Tuya IoT Platform cloud project. Sign up at
iot.tuya.com → Cloud → Development → Create
Cloud Project. Pick the data center that matches your region (e.g.
Central Europe for eu) — this must match the region your app account
uses. After creating it, the project's Overview tab shows an
Access ID (client ID) and Access Secret (client secret) — note both.
3. Link your app account to the project. In the project, open Devices → Link App Account → Add App Account, then scan the shown QR code with the Intex/Smart Life app (Me → top-right scan icon). Your pump now appears under the project's devices.
4. Run the wizard. On any computer with Python:
python3 -m pip install tinytuya
python3 -m tinytuya wizardIt asks for the Access ID, Access Secret, and a region (eu,
us, cn, or in). It then downloads your device list and writes a
devices.json file (and prints the results). Find your pump's entry — the
fields you need are:
id→ Device IDkey→ Local keyip→ the pump's LAN IP address (if blank, the wizard's network scan couldn't reach it — get the IP from your router instead)
5. Enter them in Home Assistant when adding the integration. The Access ID / Access Secret from step 2 are also exactly what you enter as the optional cloud client ID / secret to enable schedules.
Tip
Re-pairing the pump in the app rotates the local key — if local control suddenly fails with an auth error, re-run the wizard to get the new key.
Prefer a web UI over the command line? The same values are on the Tuya
site: Cloud → your project → Devices → Device List shows each pump's
Device ID, and Cloud → API Explorer → Query Device Details Info
returns the local_key.
| Entity | Description |
|---|---|
switch.intex_pool_pump |
Filtration on/off |
sensor.intex_pool_mode |
Pump mode: Normal cycle / FP run / Sleep / Boost (mode, not motor activity — the pump switch shows on/off) |
sensor.intex_pool_alarm |
normal / E93 / DIRTY / unnormal |
sensor.intex_pool_error_code |
Decoded fault code, e.g. E90; none when healthy (E93 standby is not a fault) |
sensor.intex_pool_working_time |
Hours remaining in the current run (matches the app; 0 when idle) |
binary_sensor.intex_pool_problem |
On for real faults/errors — automation-ready (ignores E93 standby) |
sensor.intex_pool_schedule |
Active timer slots, decoded details in attributes |
switch.intex_pool_slot_N |
Enable/disable schedule slot N (1–7) |
time.intex_pool_slot_N_start |
Slot start time |
number.intex_pool_slot_N_hours |
Slot run time (1–48 h) |
text.intex_pool_slot_N_days |
Repeat days: daily, once (FP) or mon,wed,fri |
button.intex_pool_start_fp |
Start a one-time FP run (~1 min from now) |
button.intex_pool_refresh |
Force an immediate re-poll (local + cloud) |
number.intex_pool_start_fp_hours |
Duration for the Start FP button |
Slot editors appear in the Configuration section of the device page; all 7 slots are shown so FP runs and app-created schedules always appear. Diagnostic extras (mesh indicator, filter switch) are disabled by default.
Each of the 7 slots holds either a repeating timer (start + duration +
days) or a dated one-time FP entry. The slot switch mirrors the app's
enable toggle; the days field accepts friendly syntax:
daily every day
mon,wed,fri specific days (full names and spaces work too)
once dated one-time entry (FP)
FP is the pump's "run long hours once, then return to the normal cycle"
feature — up to 48 h of continuous filtration for shock treatments, cloudy
water or heat waves. Set number.intex_pool_start_fp_hours, press
button.intex_pool_start_fp, and the pump starts within ~1 minute. Like the
Intex app, FP always uses slot 1 (the app's dedicated FP-mode slot), so
your repeating schedules in the other slots are never touched.
# Configure a slot in one call
action: intex_sx2100.set_schedule_slot
data:
slot: 1
enabled: true
hour: 6
minute: 0
duration: 8
days: 255 # week byte; 255 = every day
# Free a slot
action: intex_sx2100.clear_schedule_slot
data:
slot: 1Alarm notification:
alias: Pool pump alarm
triggers:
- trigger: state
entity_id: binary_sensor.intex_pool_problem
to: "on"
actions:
- action: notify.notify
data:
title: "Pool pump problem"
message: >-
The pump reports
{{ state_attr('binary_sensor.intex_pool_problem', 'code') }}.Offline alert:
alias: Pool pump offline
triggers:
- trigger: state
entity_id: binary_sensor.intex_pool_problem
to: "unavailable"
for: "00:05:00"
actions:
- action: notify.notify
data:
title: "Pool pump offline"
message: "The pump has been unreachable for 5 minutes."A ready-made card lives in
examples/dashboard-card.yaml — paste it
into a manual card.
- Tile controls for pump toggle, mode, health, refresh, and a one-tap Boost (FP) button with +/- duration input (all built-in card types)
- Collapsible, self-updating schedules: each slot is wrapped in a conditional card that renders only while the slot is in use, inside a collapsible header — so schedules appear/vanish automatically and stay tucked away until you expand them
The schedule sections use the Expander Card (install from HACS — search "Expander Card"). Pattern per slot:
- type: conditional
conditions:
- condition: numeric_state
entity: number.intex_pool_slot_1_hours
above: 0
card:
type: custom:expander-card
title: Schedule 1
expanded: false
title-card-clickable: true
cards:
- type: entities
entities:
- entity: switch.intex_pool_slot_1
name: Enabled
secondary_info: attribute
attribute: summary
- entity: time.intex_pool_slot_1_start
name: Start
- entity: number.intex_pool_slot_1_hours
name: Hours
- entity: text.intex_pool_slot_1_days
name: DaysIf you prefer no extra install, replace custom:expander-card with a plain
entities card (drop the expanded/title-card-clickable lines) — you lose
the collapsing but keep everything native.
Everything below was verified against real hardware; the DP names come from the pump's official Tuya thing model (available on any install via Device page → Download diagnostics).
Datapoints
protocol: 3.5 (3.3 -> Err 904, 3.4 -> Err 914)
DP 104: power_switch rw bool (true -> working_indicator shows FP_mode)
DP 106: filter_switch rw bool
DP 110: working_time ro value, 0-250 hours
DP 114: error_code ro bitmap; bits -> 181,180,190,191,192,193,
194,195,196,199,200,197 (label 1xx = app code Exx;
verified: bit 5 (32) set while DP 127 showed E93)
DP 115: skdl_filter rw raw — schedule blob (cloud-only)
DP 119: mesh_indicator ro bool
DP 125: working_indicator enum: working / FP_mode / sleep / boost
DP 127: warntype_indicator enum: normal / E93 / DIRTY / unnormal
(E93 = standby / power-saving, NOT a fault; DIRTY = clean the
filter; other non-normal values and any error_code bit = fault)
Each poll and command uses a fresh, non-persistent socket — persistent sockets were observed to serve stale DP values and swallow commands.
Schedule blob format (skdl_filter)
Base64-encoded, 7 fixed slots × 8 bytes:
month date hour minute worktime week control pad
Week byte (live-verified: Mon-only → 192, Wed-only → 144):
bit 7 (128) = weekly-repeat flag
bit 6 (64) = Mon bit 5 (32) = Tue bit 4 (16) = Wed bit 3 (8) = Thu
bit 2 (4) = Fri bit 1 (2) = Sat bit 0 (1) = Sun
255 = every day · 0 = dated one-time FP entry
The control byte is the app's enable toggle. Decode/encode round-trips
the real pump's blob byte-identically.
This comparison was checked against
Hovborg/intex-pool v0.21.2.
That integration is the stronger choice for a mixed Intex setup; this one goes
deeper on the SX2100 itself. If the pump is your target, the differences are
more than scope or presentation:
| Area | This integration (intex-ha) |
Hovborg/intex-pool v0.21.2 |
|---|---|---|
| Design target | Dedicated to the SX2100 / AGP Sand Filter Pump R1, with a small pump-only entity and dependency surface | A multi-device hub for water analyzers, saltwater systems, Tuya pumps, and pumps represented by another HA switch |
| Minimum Home Assistant | 2024.12.0 | 2025.8.0 |
| Start FP | First-class workflow: choose 1–48 hours with the Start FP hours entity, then press Start FP. It creates the dated one-time run used by the Intex app without disturbing the other six slots | No dedicated pump FP button or duration control; existing one-time slots are exposed through the generic schedule entities |
| Schedule enable vs delete | Mirrors the pump's two distinct operations: each slot switch changes only its control enable byte, while Clear schedule slot deliberately erases the record |
The pump-slot switch represents record presence; turning it off clears all eight slot bytes and relies on HA's remembered state to restore them later |
| Repeat days | A writable entity for every slot accepts daily, once, or friendly input such as mon,wed,fri; the verified SX2100 week-bit mapping is hidden from the user |
No per-slot weekday entity for the pump; its start-time and duration entities do not expose repeat-day editing |
| Pump schedule services | Dedicated set_schedule_slot and clear_schedule_slot services target the pump directly, use human-facing slot numbers 1–7, and preserve unspecified fields |
get_schedule can return the pump table, but the writable set_schedule service selects the saltwater-system schedule; pump edits are primarily entity-driven |
| FP/enable interpretation | Treats control as the independent enable toggle and identifies FP from the dated one-time pattern (days == 0), matching observed SX2100 blobs |
Its shared schedule summary maps control == 0 to boost; there is no dedicated SX2100 FP interpretation or action |
| DP 114 errors | True bitmap decoder: reports every set error bit, maps the thing-model labels to app codes, and keeps E93 standby out of the fault list | Applies a single integer error-code lookup to DP 114, so SX2100 bitmap values and simultaneous bits are not decoded individually |
| Actionable fault state | A ready-to-automate Problem binary sensor combines the pump's DP 127 alarm with genuine DP 114 faults and includes descriptions plus all active codes | Exposes separate pump alarm/error sensors; its broader Action required roll-up does not include a pump-only installation |
| On-demand refresh | One Refresh button immediately re-polls both the local pump and its cloud schedule | Pump data refreshes on its polling intervals; its refresh/re-test buttons belong to the water analyzer and saltwater system |
| Schedule cloud usage | Schedule polling is user-configurable from 60 seconds to 24 hours (default 15 minutes), useful for conserving the Tuya developer quota | Pump schedule polling is fixed at 10 minutes |
| Frontend footprint | Backend-only: standard HA entities and an optional YAML dashboard example, with no custom frontend or HTTP dependency | Includes an adaptive custom dashboard card served by the integration; this is an advantage when a bundled multi-device UI is preferred |
| Where the broader project wins | Focus and pump-specific behavior are intentional; it does not manage other pool equipment | Cloud discovery, protocol auto-detection, reauthentication, a bundled card, and support for several equipment types in one integration |
| Best fit | You want the most faithful SX2100 controls, FP workflow, schedule semantics, and fault decoding | You want one integration and dashboard spanning a larger pool system |
The 7×8-byte schedule blob format follows the reverse-engineering documented
in Hovborg/intex-pool (MIT). This integration is an independent
implementation.