ferrobus

CI codecov

Small Rust Modbus library with typed request/response PDUs and a reusable Modbus TCP transport.

Features

  • Typed ModbusRequest and ModbusResponse enums for the common Modbus function codes
  • Request serialization and response parsing for:
    • read coils
    • read discrete inputs
    • read holding registers
    • read input registers
    • write single coil
    • write single register
    • write multiple coils
    • write multiple registers
  • Modbus TCP transport with:
    • two-phase ModbusTcpSocketModbusTcpConnection construction
    • eager, fallible first TCP connect followed by lazy reconnect after transport failures
    • connection lifecycle on the live handle: connect, disconnect, and a subscribable ConnectionStatus with a monotonic generation counter
    • reusable actor-owned connections with bounded request-channel backpressure
    • configurable in-flight window for slow gateway-backed buses
    • retry of transient I/O failures and gateway-busy exception responses
    • per-phase timeouts for connect, write, queue wait, and on-wire response wait
    • request/response validation for transaction ID, protocol ID, unit ID, and echoed payloads
  • Support for talking to multiple unit IDs through one Modbus TCP connection handle
  • Optional CLI example behind the cli feature

Prerequisites

  • Rust 1.85 or newer (MSRV), matching the crate's Rust 2024 edition.

Installation

Add the crate to your project:

[dependencies]
ferrobus = "0.1.0"

Breaking changes

  • The convenience constructor ModbusTcpConnection::connect(host, port, unit_id) is renamed to ModbusTcpConnection::open(host, port, unit_id). The connect name now belongs to the live-handle method ModbusTcpConnection::connect(&self), which reopens the socket of the actor a handle already owns. Existing call sites can either be renamed to open(...) or replaced with the equivalent ModbusTcpSocket::new(host, port, unit_id).connect().await.

Library usage

Create a typed request and send it over Modbus TCP:

use ferrobus::tcp::ModbusTcpConnection;
use ferrobus::{ModbusRequest, ModbusResponse};

#[tokio::main]
async fn main() -> Result<(), ferrobus::ModbusError> {
    let connection = ModbusTcpConnection::open("127.0.0.1", 502, 1).await?;

    let response = connection
        .send_message(&ModbusRequest::ReadHoldingRegisters {
            starting_address: 100,
            quantity: 2,
        })
        .await?;

    match response {
        ModbusResponse::ReadHoldingRegisters { registers } => {
            println!("registers: {registers:?}");
        }
        other => {
            println!("unexpected response: {other:?}");
        }
    }

    Ok(())
}

The TCP client accepts host names or numeric IP addresses. ModbusTcpConnection::open(...) is async and fallible: it opens the first TCP socket eagerly, then the live actor handle retries short-lived I/O failures and reconnects lazily after transport teardown. Internally, cloned handles send commands over a bounded channel to one actor task that owns the socket and MBAP codec; this provides backpressure under burst load. Cloned handles, including those returned by with_unit_id, may issue requests concurrently; responses are matched by MBAP transaction ID. Writes are serialized by the actor and a cancellation in one caller cannot interrupt a partially written Modbus TCP frame.

Use send_message_with_unit_id or with_unit_id(...) when talking to multiple devices behind one Modbus TCP gateway.

Connection lifecycle

The live ModbusTcpConnection handle owns the connection lifecycle. It is a handle to one background actor that owns the socket; clones and with_unit_id(...) derivations share that actor.

  • connect().await opens the actor's socket. It is idempotent: if a socket is already open, the actor acknowledges without dialing again. It reuses the existing actor, so no second actor is spawned.
  • disconnect().await drops the current socket and fails pending requests, but keeps the actor alive.
  • status() returns a ConnectionStatus snapshot; watch_status() returns a tokio::sync::watch::Receiver<ConnectionStatus> so callers can await transitions instead of polling. is_connected().await remains available as status().connected.

Reconnection is on-demand, not a background loop. Any read/write/EOF failure tears the socket down; the next request to reach the actor opens a fresh one. There is no reconnect timer, task, or backoff inside the actor: reconnect policy stays with the caller, and ModbusTcpRetry covers same-call retry.

Generation contract

ConnectionStatus::generation counts successful socket establishments on one actor:

event status
before the first connect { connected: false, generation: 0 }
after the first successful connect { connected: true, generation: 1 }
after a teardown { connected: false, generation: 1 }
after a failed connect attempt unchanged
after the next successful connect { connected: true, generation: 2 }

The counter never decreases. A changed generation therefore means the socket was replaced, regardless of how many drop/reconnect cycles happened in between and regardless of when the observer sampled — a bool connection flag collapses true → false → true and cannot express this. The counter is per actor: a handle from a new ModbusTcpSocket::connect() starts its own count at 1.

If your application negotiates device state over the connection (word order, scaling calibration, arming a device-side watchdog), cache the generation alongside that state and re-negotiate when it moves — the device may have rebooted underneath you:

use ferrobus::tcp::ModbusTcpConnection;

struct Session {
    connection: ModbusTcpConnection,
    negotiated_at: u64,
}

impl Session {
    async fn ensure_negotiated(&mut self) -> Result<(), ferrobus::ModbusError> {
        let status = self.connection.status();
        if !status.connected {
            self.connection.connect().await?;
        }
        let generation = self.connection.status().generation;
        if generation != self.negotiated_at {
            // the socket was replaced: re-run device negotiation here
            self.negotiated_at = generation;
        }
        Ok(())
    }
}

Do not wrap the handle in Mutex<Option<ModbusTcpConnection>> and discard it on the first I/O error. Dropping the handle stops requests from ever reaching the actor, which is exactly what defeats its on-demand reconnect. Keep the handle and watch the generation instead.

To react to transitions instead of polling:

use ferrobus::tcp::ModbusTcpConnection;

# async fn run(connection: ModbusTcpConnection) {
let mut status = connection.watch_status();
while status.changed().await.is_ok() {
    let current = *status.borrow_and_update();
    println!("connected={} generation={}", current.connected, current.generation);
}
# }

Word order for wide values

Modbus protocol fields, MBAP headers, addresses, quantities, and each individual 16-bit register are always encoded big-endian on the wire. ferrobus::WordOrder only controls how already-decoded consecutive registers are combined into 32-bit and 64-bit application values.

use ferrobus::WordOrder;

let registers = [0x0000, 0x3F80];
let value = WordOrder::LittleEndian.decode_f32(registers);
assert_eq!(value.to_bits(), 1.0f32.to_bits());

Use WordOrder::BigEndian (the default) for most-significant-word-first devices and WordOrder::LittleEndian for least-significant-word-first devices. Decode helpers are available for u32, i32, f32, u64, i64, and f64, including block decode methods that validate register counts.

Timeouts and retries

ModbusTcpConnection::open(...) uses sensible defaults for connect, write, and response timeouts. The write timeout covers both sending the frame and flushing the socket. If you need custom limits, configure a ModbusTcpSocket before calling connect().await.

use std::time::Duration;

use ferrobus::tcp::{ModbusTcpFlowControl, ModbusTcpRetry, ModbusTcpSocket, ModbusTcpTimeouts};

let connection = ModbusTcpSocket::new("localhost", 502, 1)
    .with_timeouts(ModbusTcpTimeouts {
        connect_timeout: Duration::from_secs(2),
        write_timeout: Duration::from_secs(2),
        response_timeout: Duration::from_secs(2),
    })
    .with_flow_control(ModbusTcpFlowControl::serial_gateway())
    .with_retry(Some(ModbusTcpRetry {
        initial_delay: Duration::from_millis(100),
        max_elapsed: Duration::from_secs(1),
        ..ModbusTcpRetry::default()
    }))
    .connect()
    .await?;

Flow control is actor-owned and validated when ModbusTcpSocket::connect is awaited: ModbusTcpFlowControl::max_in_flight caps requests on the wire, and max_queue_depth is the bounded backlog that applies backpressure to callers. Invalid flow-control settings return ModbusError::ValidationError from socket connect. Use ModbusTcpFlowControl::serial_gateway() for RTU gateways that drain one serial bus sequentially. Queue wait is bounded by queue_timeout; the response_timeout clock starts only after the actor successfully writes the frame to the socket. A single response timeout fails that transaction, quarantines its transaction ID to avoid late-response aliasing, and keeps the TCP socket open. If a connection attempt fails while callers are parked on a full request queue, one parked caller may be admitted after the actor drains the backlog and can observe one additional failing connect attempt before its request fails or its queue deadline elapses.

By default, transient TCP connect/write/read/queue failures and gateway-busy exception responses (0x05, 0x06, 0x0A, 0x0B) are retried with exponential backoff starting at 500 ms, multiplied by 1.5, with jitter, and bounded only by max_elapsed (2 s). Set max_times to cap the number of retries as well. To disable same-call retry, pass with_retry(None); the first transient error is returned to the caller for that call, but the connection state is still invalidated and the next call reconnects lazily.

Error handling

Transport and protocol failures are reported with cloneable ModbusError values, including:

  • connect, write, and read errors/timeouts
    • I/O error variants carry Arc<std::io::Error>; pattern matching still lets callers bind the error and call err.kind() through Arc deref.
  • malformed or invalid responses
  • Modbus exception responses
  • transaction ID, protocol ID, and unit ID mismatches
  • request/response mismatches
  • request validation errors
  • invalid retry configuration as ValidationError (not retried)

CLI example

The repository includes a modbus_cli example for interactive Modbus TCP reads and writes across all supported function codes.

Enable the cli feature when building or running it so the extra CLI-only dependencies are not pulled into library-only builds.

Show the CLI help:

cargo run --features cli --example modbus_cli -- --help

The CLI is organized as nested read/write subcommands:

modbus_cli [OPTIONS] read <coils|discrete|holding|input> <ADDRESS> <QUANTITY>
modbus_cli [OPTIONS] write <coil|register|coils|registers> <ADDRESS> <VALUE...>

Examples:

cargo run --features cli --example modbus_cli -- read coils 0 8
cargo run --features cli --example modbus_cli -- --address 192.168.1.10 read holding 100 4
cargo run --features cli --example modbus_cli -- read holding 100 2 --as f32 --word-order little
cargo run --features cli --example modbus_cli -- write coil 12 on
cargo run --features cli --example modbus_cli -- --output hex write register 200 4660
cargo run --features cli --example modbus_cli -- write coils 16 1 0 1 1
cargo run --features cli --example modbus_cli -- write registers 300 10 20 30
cargo run --features cli --example modbus_cli -- -a 192.168.0.89 write register 5004 6000

The CLI accepts:

  • coil values as 1, 0, true, false, on, or off
  • register output in decimal or hex
  • holding/input register reads can decode u32, i32, f32, u64, i64, or f64 via --value-type/--as; --word-order {big,little} applies only to these wide read values and does not change Modbus wire byte order
  • global connection options such as --address, --port, --unit-id, and --transaction-id