bellows

A terminal-based ventilation simulator and waveform visualiser for anaesthesia and ICU education.

bellows is a Python TUI for exploring mechanical ventilation waveforms in real time. It simulates a single-compartment lung with selectable pressure-volume mechanics and renders ventilator traces directly in the terminal.

It is intended for education, demonstration, and experimentation. It is not clinical software — see Safety and scope.

Mechanical ventilation in your terminal.


Running

uv run bellows

Python 3.13+ via uv. Dependencies (Textual) are pulled in automatically.

Startup options can seed the interactive simulator:

uv run bellows --mode PRVC --vt 450 --rr 16 --peep 8
uv run bellows tui --mode APRV --p-high 26 --p-low 5 --t-high 4 --t-low 0.6

Controls

The left panel is the main control surface.

Key Action
up / down Select a row in the left control panel
left / right Decrease / increase the selected setting
enter Open a picker, or toggle the selected row (mode, preset, waveform, ...)
space Pause / resume
tab Show / hide the left control panel
p Show / hide the pressure-volume loop panel
r Reset simulation
q Quit

Ventilator setting changes are queued and applied at the next breath boundary, so changing mode or any ventilator setting does not distort the current breath mid-cycle. Patient parameter changes (lung model, compliance, resistance, presets) take effect immediately.


Ventilator modes

Mode What it does Adjustable settings
VCV Volume control. Fixed inspiratory flow delivers the configured tidal volume. VT, RR, PEEP, I:E
PCV Pressure control. Decelerating flow toward a target inspiratory pressure above PEEP. Pinsp, RR, PEEP, I:E
PRVC Pressure-regulated volume control. PCV-shaped breath; applied Pinsp adapts each breath to track a target VT. The applied Pinsp is shown next to the VT target. VT (target), RR, PEEP, I:E
APRV Airway pressure release. Pressure alternates between P_high (held for T_high) and a brief release to P_low (for T_low). Passive — no spontaneous effort is modelled yet, so the trace shows only the mandatory pressure swings. P_high, P_low, T_high, T_low

Patient model

The simulation uses a single-compartment lung driven by

Paw = P_elastic(V, phase) + R * Flow

P_elastic(V) is the lung's absolute elastic recoil at volume V. PEEP is the airway pressure the ventilator holds at end-expiration; the lung settles to whatever volume satisfies P_elastic(V_eq) = PEEP. The volume trace shows absolute lung volume, so raising PEEP visibly shifts the trace baseline up (recruitment) and the operating point onto a different part of the PV curve.

Lung models

Model P_elastic What it's useful for
Linear V / C Constant compliance, straight PV loop. Simplest model and the default.
Venegas sigmoid V(P) = a + b/(1 + exp(-(P-c)/d)) Lower inflection (recruitment) and upper plateau (overdistension). Driving pressure, "best PEEP", protective vent.
Venegas+H Venegas sigmoid + inflation/deflation offset Adds hysteresis between limbs. Surfactant-deficient teaching cases, deflation-limb PEEP titration.

Live-edit parameters depend on the selected model:

Model Live parameters
Linear compliance
Venegas inflection, slope, recruitable volume
Venegas+H inflection, slope, recruitable volume, hysteresis

Resistance and a patient preset are available across all models. Each model carries its own preset list (Linear: Normal / Stiff / Restrictive / Obstructed / Severe obstruction; Venegas variants add Recruitable ARDS / Non-recruitable ARDS / Surfactant-deficient). Manual edits change the displayed preset to Custom.

CO2 remains a simplified capnography trace in the simulator/TUI only. The web UI omits CO2 for now because it needs a more defensible physiological model before becoming a prominent browser feature.


Waveforms and numerics

Waveforms (fixed time axis, fixed y-axis ranges, smoother braille-cell rendering, selectable visibility, one-shot scale fit):

  • pressure, cmH2O
  • flow, L/min
  • volume, mL (absolute)
  • CO2, kPa — TUI only; optional, hidden by default

Monitor numerics, computed from the last completed breath:

  • Ppeak (cmH2O)
  • Pmean (cmH2O)
  • VT (mL)
  • MV (L/min) — uses the actual cycle length, so APRV's minute volume is correct
  • EtCO2 (kPa) — TUI only

Architecture

The simulation is decoupled from the UI so it can evolve independently.

bellows/
    app.py                      Textual application and UI state

    simulation/
        engine.py               simulation loop, breath timing, stats
        state.py                settings, patient mechanics, samples
        lung_model.py           Linear / Venegas / Venegas+H
        presets.py              per-model patient presets

    ventilator/
        modes/
            base.py             VentilatorMode base, helpers, LastBreathStats
            vcv.py              volume control
            pcv.py              pressure control
            prvc.py             pressure-regulated volume control
            aprv.py             passive airway pressure release

    waveforms/
        buffers.py              timestamped rolling trace buffers

    ui/
        waveform.py             terminal waveform renderer

tests/
    helpers.py                  shared simulation test helpers
    modes/
        test_modes.py           directional tests for VCV / PCV / PRVC / APRV
    simulation/
        test_lung_model.py      lung-model and PEEP-recruitment tests
        test_state.py           settings, reset, and patient preset contracts

Design choices:

  • simulation tick and render refresh are decoupled
  • waveform buffers store timestamped samples; the UI observes them rather than owning physiology
  • ventilator modes carry their own per-breath state via on_activate / on_breath_end hooks
  • ventilator setting changes queue and apply at breath boundaries; patient changes apply immediately
  • lung mechanics are pluggable behind a LungModel protocol

Safety and scope

bellows is an educational simulator. It must not be used for:

  • clinical decision-making
  • ventilator setup
  • patient monitoring
  • diagnosis
  • treatment recommendations

Development

Run the test suite:

uv run python -m unittest discover tests

Quick compile check:

uv run python -m compileall bellows tests

Planned work, known limitations, and future-feature notes live in TODO.md.