A terminal-based ventilation simulator and waveform visualiser for anaesthesia and ICU education.
bellows is a Python TUI for exploring mechanical ventilation waveforms in real time. It simulates a single-compartment lung with selectable pressure-volume mechanics and renders ventilator traces directly in the terminal.
It is intended for education, demonstration, and experimentation. It is not clinical software — see Safety and scope.
Mechanical ventilation in your terminal.
uv run bellowsPython 3.13+ via uv. Dependencies (Textual) are pulled in automatically.
Startup options can seed the interactive simulator:
uv run bellows --mode PRVC --vt 450 --rr 16 --peep 8
uv run bellows tui --mode APRV --p-high 26 --p-low 5 --t-high 4 --t-low 0.6The left panel is the main control surface.
| Key | Action |
|---|---|
up / down |
Select a row in the left control panel |
left / right |
Decrease / increase the selected setting |
enter |
Open a picker, or toggle the selected row (mode, preset, waveform, ...) |
space |
Pause / resume |
tab |
Show / hide the left control panel |
p |
Show / hide the pressure-volume loop panel |
r |
Reset simulation |
q |
Quit |
Ventilator setting changes are queued and applied at the next breath boundary, so changing mode or any ventilator setting does not distort the current breath mid-cycle. Patient parameter changes (lung model, compliance, resistance, presets) take effect immediately.
| Mode | What it does | Adjustable settings |
|---|---|---|
| VCV | Volume control. Fixed inspiratory flow delivers the configured tidal volume. | VT, RR, PEEP, I:E |
| PCV | Pressure control. Decelerating flow toward a target inspiratory pressure above PEEP. | Pinsp, RR, PEEP, I:E |
| PRVC | Pressure-regulated volume control. PCV-shaped breath; applied Pinsp adapts each breath to track a target VT. The applied Pinsp is shown next to the VT target. | VT (target), RR, PEEP, I:E |
| APRV | Airway pressure release. Pressure alternates between P_high (held for T_high) and a brief release to P_low (for T_low). Passive — no spontaneous effort is modelled yet, so the trace shows only the mandatory pressure swings. |
P_high, P_low, T_high, T_low |
The simulation uses a single-compartment lung driven by
Paw = P_elastic(V, phase) + R * Flow
P_elastic(V) is the lung's absolute elastic recoil at volume V. PEEP is the airway pressure the ventilator holds at end-expiration; the lung settles to whatever volume satisfies P_elastic(V_eq) = PEEP. The volume trace shows absolute lung volume, so raising PEEP visibly shifts the trace baseline up (recruitment) and the operating point onto a different part of the PV curve.
| Model | P_elastic |
What it's useful for |
|---|---|---|
| Linear | V / C |
Constant compliance, straight PV loop. Simplest model and the default. |
| Venegas | sigmoid V(P) = a + b/(1 + exp(-(P-c)/d)) |
Lower inflection (recruitment) and upper plateau (overdistension). Driving pressure, "best PEEP", protective vent. |
| Venegas+H | Venegas sigmoid + inflation/deflation offset | Adds hysteresis between limbs. Surfactant-deficient teaching cases, deflation-limb PEEP titration. |
Live-edit parameters depend on the selected model:
| Model | Live parameters |
|---|---|
| Linear | compliance |
| Venegas | inflection, slope, recruitable volume |
| Venegas+H | inflection, slope, recruitable volume, hysteresis |
Resistance and a patient preset are available across all models. Each model carries its own preset list (Linear: Normal / Stiff / Restrictive / Obstructed / Severe obstruction; Venegas variants add Recruitable ARDS / Non-recruitable ARDS / Surfactant-deficient). Manual edits change the displayed preset to Custom.
CO2 remains a simplified capnography trace in the simulator/TUI only. The web UI omits CO2 for now because it needs a more defensible physiological model before becoming a prominent browser feature.
Waveforms (fixed time axis, fixed y-axis ranges, smoother braille-cell rendering, selectable visibility, one-shot scale fit):
- pressure, cmH2O
- flow, L/min
- volume, mL (absolute)
- CO2, kPa — TUI only; optional, hidden by default
Monitor numerics, computed from the last completed breath:
Ppeak(cmH2O)Pmean(cmH2O)VT(mL)MV(L/min) — uses the actual cycle length, so APRV's minute volume is correctEtCO2(kPa) — TUI only
The simulation is decoupled from the UI so it can evolve independently.
bellows/
app.py Textual application and UI state
simulation/
engine.py simulation loop, breath timing, stats
state.py settings, patient mechanics, samples
lung_model.py Linear / Venegas / Venegas+H
presets.py per-model patient presets
ventilator/
modes/
base.py VentilatorMode base, helpers, LastBreathStats
vcv.py volume control
pcv.py pressure control
prvc.py pressure-regulated volume control
aprv.py passive airway pressure release
waveforms/
buffers.py timestamped rolling trace buffers
ui/
waveform.py terminal waveform renderer
tests/
helpers.py shared simulation test helpers
modes/
test_modes.py directional tests for VCV / PCV / PRVC / APRV
simulation/
test_lung_model.py lung-model and PEEP-recruitment tests
test_state.py settings, reset, and patient preset contracts
Design choices:
- simulation tick and render refresh are decoupled
- waveform buffers store timestamped samples; the UI observes them rather than owning physiology
- ventilator modes carry their own per-breath state via
on_activate/on_breath_endhooks - ventilator setting changes queue and apply at breath boundaries; patient changes apply immediately
- lung mechanics are pluggable behind a
LungModelprotocol
bellows is an educational simulator. It must not be used for:
- clinical decision-making
- ventilator setup
- patient monitoring
- diagnosis
- treatment recommendations
Run the test suite:
uv run python -m unittest discover testsQuick compile check:
uv run python -m compileall bellows testsPlanned work, known limitations, and future-feature notes live in TODO.md.