TWC3 Charge Control (ESP32-S3-RS485-CAN → Tesla Wall Connector 3)

Local control of Tesla Wall Connector Gen 3 charging current over RS485, by emulating a Neurio/Generac CT-clamp meter (TWC3's Home Load Management input), driven by real per-phase current/power data mirrored in from Home Assistant (originally from a Shelly Pro 3EM on the main incomer). No cloud integration at all — session start/stop isn't driven by this project or any cloud API (Tesla Fleet API, Tessie, etc.); the car starts charging on its own the moment it's plugged in or asked to via the Tesla app, and stops/restarts itself in response to the current this firmware publishes (reported, see "Publication law" below) — same as it would against any other Home Load Management meter.

Home Assistant is a hard dependency: real-time power control runs over ESPHome's native API connection to HA (both the real current/power data and charge_from_grid), not a cloud service — if that connection or the mirrored HA entities go stale, the firmware fails safe (0A available).

Verified in practice: with live, correlated data, TWC3 keeps responding continuously throughout the whole charging session (not just at its start).

📊 Full decision tree — a diagrammed, section-by-section walkthrough of recompute_ct, including the zone-steering algorithm and the measured TWC3 reaction-curve findings.

How it works

Shelly Pro 3EM (main incomer, L1/L2/L3, includes the TWC branch)
   → HA (Shelly integration): your ha_current_a/b/c_entity + ha_power_a/b/c_entity (secrets.yaml)
   → ESP32 (sensor: platform: homeassistant, real-time push over the API connection)
   → globals shelly_a/b/c_current + shelly_a/b/c_power (signed, for flow direction)

TWC3's own /api/1/vitals (twc_vitals_ip, polled directly, diagnostic AND
   R1-floor/household-split input -- see "Publication law" below)

HA input_boolean (entity ID set by ha_charge_from_grid_entity in secrets.yaml,
mirrored via ESPHome's homeassistant: binary_sensor)
   → switches between two modes:

  GRID mode (ON):  car gets the max safe current (BOTH breakers protected)
  FVE mode (OFF):  self-balancing loop toward zero grid exchange
                   (export -> car takes more, import -> car backs off)

ESP32 computation (see recompute_ct in twc-control.yaml) -- a "publication
law", not a proportional availability calculation, see below for why:
  desired_avail = self-balancing target (household-only, car-free signal)
  worst         = max(signed_a, signed_b, signed_c)  (car-INCLUSIVE)
  o_raw         = worst + (twc_breaker_limit_a - desired_avail)
  reported      = o_raw <= limit ? o_raw
                    : limit + clamp(excess_gain*(o_raw-limit), law_nudge_min_a, excess_max_a)
   → RS485 Modbus RTU (registers 0xF4-0xFC), published SYMMETRICALLY on all 3
   → TWC3 applies the limit to the car

Session start/stop: entirely TWC3's own doing, not this project's — begins
   when the car is plugged in or told to charge (Tesla app or otherwise),
   ends/restarts on its own based on `reported` (see "TWC3 reaction curve"
   in the decision tree above)

Publication law (why this isn't a simple availability formula)

TWC3 firmware 26.26.1 does not proportionally track reported below its own configured breaker limit at all — confirmed live, repeatedly: it just charges toward its own internal ceiling regardless of what's reported, as long as that value stays under the limit. It only reacts once reported crosses the limit by a margin — confirmed live, consistently ~1.1-1.2A above twc_breaker_limit_a, across independent trials and two different HA data sources. This ruled out the entire earlier "compute a precise available current" family of designs (see the numbered history further below, kept for context) — none of that fine-grained math has any effect on TWC3's actual behavior on this firmware version.

The current design is adapted from an independently-developed, live- validated open-source solution to this identical TWC3 behavior: zany92/tesla-loadpilot (verified against its actual source, esphome/packages/twc-core.yaml, not just its docs — an earlier pass here mis-implemented a "decaying tail" its docs described that doesn't actually exist in the real code, and that bug is described further below as an example of why this was verified against source).

  • Below the limit: reported tracks the worst-phase, car-inclusive real current 1:1 (worst) — no gain, no damping. TWC3 ignores the exact value here for control purposes, but still needs to see it move in lockstep with its own ramping current for its live plausibility check; diluting that slope (tried and reverted, see history) risks a distrust latch instead.
  • desired_avail: the self-balancing target — computed from the household-only signal (TWC3's own vitals API gives the car's OWN per-phase current directly, subtracted out of Shelly's combined reading, eliminating the self-referential feedback loop at its source instead of damping it) — and asymmetrically slew-rate-limited (desired_avail_slew_down_a_per_s, 1A/s; desired_avail_slew_up_a_per_s, 10A/s — recovering availability is treated as protective/instant, only declines are throttled). This mirrors the reference project's own architecture: its "budget" is a slow/external quantity, kept separate from the fast worst term used for correlation. Confirmed live: without this slew limit, Shelly and TWC3's own vitals API — two independently-polled sources — can briefly disagree by several amps during a fast multi-phase engagement (one lagging the other's newly-engaged-phase reading), spiking reported right at the critical startup window.
  • Above the limit: the excess is compressed (excess_gain, default 0.75) and capped (excess_max_a, default 1.2A — kept close to, not below, the confirmed reaction margin) instead of climbing further.
  • R1 hard floor: with the contactor closed, every phase carries at least the vehicle's own measured current (from vitals) — applied to the input signal, not patched onto the output afterward (per the reference project). A lower reading is physically impossible and would latch a distrust state.
  • Anti-glitch firewall (asymmetric, per the reference project): a rise in real current (or a gentle drop) is trusted immediately; a sudden drop (glitch_drop_a, default 3A) is held at the last trusted value until 2 consecutive samples agree on a new value (within glitch_confirm_tol_a) — confirmed live, a single stale/desynced Shelly sample dropped >4A in <10ms right during a fast multi-phase engagement (physically impossible for a real ramp).
  • Dither (dither_amplitude_a, ±0.05A alternating at 1Hz, always on including fail-safe) — reported is never perfectly static for long.
  • Symmetric publication: the final value is published identically on all 3 Modbus registers — TWC3's own service loop expects min == mean == max to correctly engage at the true constraint, regardless of which phase is actually weakest.
  • Escalation (secondary safety net, 2-stage step per the reference project, not a continuous ramp): if o_raw stays above the limit continuously for escalation_timeout_ms (default 120s), force reported to at least law_nudge_min_a past the limit; if it's still there after 2×escalation_timeout_ms, force it to escalation_kick_a (default 1.5A) — safely past the confirmed reaction margin.

Both breakers (twc_breaker_limit_a and main_breaker_limit_a) still clamp desired_avail before any of the above — main-breaker protection is applied after slewing, so it's never delayed, regardless of mode.

GRID mode: desired_avail = twc_breaker_limit_a (max allowed, subject to the same breaker clamps).

FVE mode: desired_avail is the self-balancing target — averaged across the household-only signal on all 3 phases (aggregate/net billing, switch.*_aggregate_balance_metering) or the weakest phase (per-phase billing, default), plus the manual fve_offset_kw (number.*_fve_offset, runtime-adjustable in HA).

Fail-safe: if any of the 6 HA-mirrored current/power entities has been reporting unavailable/unknown continuously for shelly_unavailable_debounce_ms (default 10s), OR the HA API client isn't connected, full consumption is reported on all phases → TWC3 gets 0A available for the car.

Availability is driven by HA's own reported state, not a fixed no-update timeout — a timeout can't tell "Shelly went offline" apart from "the load just isn't changing" (HA/Shelly only push a new value when one actually occurs), which caused false staleness during genuinely stable load. ESPHome's homeassistant sensor publishes NAN whenever the entity's HA state fails to parse as a number (i.e. exactly on unavailable/unknown), which is what's checked. The debounce only absorbs a brief HA-reported outage (e.g. Shelly on a flaky powerline/mesh link) — HA gets a chance to reconnect on its own before the fail-safe reacts. A periodic safety-net recompute (recompute_interval, independent of any HA push) keeps the debounce timer itself re-evaluated even if HA stops sending updates without dropping the API connection.

GRID mode

desired_avail = twc_breaker_limit_a (the max either breaker allows), subject to the same publication law and breaker clamps described above.

FVE mode — per-phase (default, aggregate metering OFF)

desired_avail tracks the weakest phase's household-only signal (shelly_x_power sign, car's own draw subtracted out via the TWC vitals API): exporting → back off less / take more; importing → back off.

FVE mode — aggregate/net balance metering (optional, per-switch)

Some utilities net import/export across all 3 phases together for billing, instead of settling each phase separately. In that case, blocking or under-using charging just because one phase individually imports (while others export a lot more) is overly conservative — the switch.*_aggregate_balance_metering entity (default OFF) switches desired_avail from the weakest phase to the average of the household-only signal across all 3 phases instead.

Either way, the per-phase main-breaker safety check (main_breaker_limit_a - real) still applies unconditionally, after slewing, so it's never delayed.

TWC3 reaction curve (threshold-probe findings, twc_breaker_limit_a=20A)

Live-tested by publishing a fixed, manually-stepped reported value (a dedicated diagnostic test mode, test/threshold-probe branch — not part of production) and watching twc_vitals_vehicle_current for a reaction. The reaction is not a sharp on/off threshold — it behaves like a time-integrated/cumulative response: every tested value above the limit eventually causes a reduction given enough time, there is no value that holds forever, but how fast it reacts (and how far it goes before plateauing) depends heavily on how far past the limit it is:

excess over twc_breaker_limit_a observed reaction
+0.9A first visible reduction only after tens of seconds; can plateau for a while (e.g. 13.1A→10A over ~175s, then flat) but is not safe indefinitely — held long enough it resumes declining (10A→11A→10A over further ~80-175s in separate trials)
+1.0 / +1.05A reduction starts after ~20s in an isolated, static test, then a gradual decline — but this ~20s figure did not generalize to real/dynamic conditions: one live stop happened after only ~4s at flat +1.0A when the car's actual current was already low/near the floor (less headroom to brake before hitting it), and another sustained ~8 minutes of continuous +0.9-1.0A holding (actual stabilized just above the floor, a genuine small deficit) before TWC3 aborted anyway
+1.1A and above (1.2/1.5/2.0A tested) fast/cascading reduction within seconds, full stop in ~3s; reaction speed saturates around +1.1A — going higher doesn't react meaningfully faster

Recovery from a cascade requires fully exiting to the natural/low published value — nudging the published value down slightly mid-cascade does not reliably halt it once started.

Practical implication: there's no single excess value that's both "fast enough to react to a real deficit" and "gentle enough to never overshoot into a stop" — a continuous law has to pick one operating point and live with its trade-off. This is what motivated zone steering below: instead of one value, react with an explicit sequence of increasingly firm bands, and escalate over time only if the gentler ones aren't working.

Zone steering (graceful degradation for transient deficits)

The classic publication law above (a single, continuous excess value) reacts to a sudden production drop (a cloud) either too weakly — sitting in a real deficit for minutes before escalation_timeout_ms kicks in — or, if tuned more aggressively, too strongly, cascading into a full stop within seconds per the reaction curve above. Zone steering is an alternative response, active only once the classic law's own computation would already publish at or above twc_breaker_limit_a while charging: instead of one excess value, it publishes one of 4 discrete bands, chosen by comparing the vehicle's own actual current (twc_vitals_vehicle_current) against desired_avail (the target):

  • INCREASE (actual < target - tolerance, and past a post-brake recovery cooldown): publish twc_breaker_limit_a - 1.0A, i.e. let the classic law's own below-limit tracking take back over.
  • HOLD (small deadband around target): publish twc_breaker_limit_a + 0.2A — inside TWC3's ignored range, no reaction, but keeps reported moving (correlation-safe) without drifting toward a stop.
  • SLOW / DESCEND_TO_FLOOR (actual moderately over target): publish twc_breaker_limit_a + 0.9A (confirmed-gentle per the reaction curve above; +0.9A when actual is already below number.*_zone_steering_low_current_threshold_a, +1.0A otherwise) — deliberately below the fast-cascade zone, giving the car time to ease down instead of dropping out.
  • HARD (actual far over target, or the stuck-timeout below has fired): publish twc_breaker_limit_a + 1.1A — the confirmed-fast, reserved-for-a-real-persistent-excess band.

TWC3's own live plausibility/correlation check on reported (§/"Publication law" above) appears to only really be active during the initial charging ramp-up — once the limit is reached and zone steering takes over, it doesn't seem to be a factor anymore, behavior is driven purely by the reaction-curve timing above. Not confirmed as a hard rule, but consistent with everything observed so far, and part of why zone steering can safely hold a fixed band value for multiple seconds without a correlation-distrust stop the way a static value would during ramp-up.

Auto-engage / handoff (latch): engages the instant the classic computation would publish >= twc_breaker_limit_a while charging, and stays engaged through normal fluctuation. The moment actual reaches number.*_zone_steering_floor_a inside the HARD band, it disengages immediately and hands control back to the classic algorithm's own grace-period mechanism (rather than maintaining a separate floor-hold state with its own timer) — confirmed live that holding a separate floor-hold state let actual stabilize just above the floor (a real, small, sustained deficit) for 8+ minutes without ever escalating or handing off, and TWC3 eventually aborted anyway. Disengages fully on !car_charging, re-engaging fresh on the next threshold hit.

Stuck-timeout escalation (number.*_zone_steering_stuck_timeout_s, default 60s, 5-900s range): if actual shows no real progress (no genuine >0.3A decrease from its baseline) while braking is needed for this long, SLOW/DESCEND_TO_FLOOR escalate to the HARD excess (+1.1A) instead of holding the weaker brake value indefinitely — added directly in response to the 8-minute stuck case above, for when actual never quite reaches the floor at all.

Minimum-dwell gate (number.*_zone_steering_min_dwell_s, default 3s): confirmed live, desired_avail's fast recovery slew combined with a tight tolerance could make the target jitter across a band boundary several times per second, and every such flip reset TWC3's own internal "sustained excess" timer — so a correction never ran long enough uninterrupted to have any effect. The gate holds the last published value sticky for at least this long before accepting an escalation to a firmer band. Asymmetric: a decrease (easing off) is always accepted instantly, matching the "rises trusted immediately, only firming up needs caution" pattern used throughout this design (anti-glitch firewall, R1 floor, the release logic above) — only an increase in severity is dwell-gated.

Recovery-hold cooldown (number.*_zone_steering_recovery_hold_s, default 10s): blocks INCREASE for this long after any braking cycle, falling through to HOLD instead — confirmed live, without it a brief dip of actual just under target right after a correction triggered an immediate ramp back up, undoing the correction it had just made.

Entities: switch.*_zone_steering_mode (default ON, enables the whole mechanism), binary_sensor.*_zone_steering_engaged (is it actually steering right now vs. the classic algorithm running normally), number.*_zone_steering_tolerance_a (0.5A default), number.*_zone_steering_hard_excess_a (3.0A default — deadband before the HARD band, distinct from the fixed +1.1A HARD excess value itself), number.*_zone_steering_floor_a (6.5A default — where steering hands off), number.*_zone_steering_low_current_threshold_a (8.0A default) and number.*_zone_steering_slow_brake_excess_a (0.9A default — the gentler SLOW excess used below that threshold), number.*_zone_steering_recovery_hold_s, number.*_zone_steering_min_dwell_s, number.*_zone_steering_stuck_timeout_s.

Design history — earlier algorithm generations, kept for context. The generations below all predate the discovery that TWC3 FW 26.26.1 doesn't proportionally track reported below its own breaker limit at all — they were solving a real problem (TWC3's live correlation check, which is still real and still relevant) with a fine-grained "compute exact available current" model that turned out not to matter for actual control on this firmware. Kept here because the correlation-safety lessons (1:1 slope tracking, no dilution, no smoothing/EMA) still apply directly to the current design's worst term:

  1. First attempt: report the same phase-averaged value on all 3 registers. Broke correlation — while a phase ramps up alone (TWC3 engages L1 → L2 → L3 sequentially, not all at once), averaging diluted that phase's own signal to ~1/3 of its real slope. TWC3 saw the mismatch and stopped charging within seconds of starting.
  2. Second attempt: keep each phase's own real current as the base (fixes correlation), rescue an importing phase only up to breakeven using surplus borrowed from exporting phases. Correlation-safe, but since TWC3 applies min(avail_a, avail_b, avail_c)-equivalent logic, a single weak/importing phase capped at breakeven still bottlenecked the whole session to ~0A even with a large net export.
  3. Third attempt: water-filling — raise the weakest phase(s) all the way toward the strongest. Turned out to be an actual double-counting bug (spending the same surplus pool twice), not just an over-optimization.
  4. Fourth: avail_mode_x = max(strict_x, pool/3) — a correlation-safe, no-double-counting ceiling. Solved the availability-math problem correctly, but was superseded once the threshold-ignoring firmware behavior was confirmed and made the whole availability-math approach moot (see "Publication law" above).
  5. A gain-damped self-balancing loop (self_balance_gain) and an EMA/ low-pass smoothing attempt were both tried and reverted for this same underlying reason — see "Publication law" above for the design that replaced them (household-only signal + slew-rate limiter, eliminating the feedback loop and the correlation-vs-lag trade-off at the source instead of damping it).

Escalation (escalation_timeout_ms) was originally a continuous ramp (+0.1A every 5s while reported sat at the limit) — useful as a diagnostic tool to map TWC3's exact reaction threshold live, but replaced with the current 2-stage step (see "Publication law" above) to match the independently-validated reference design once the threshold was confirmed.

Disabling external control (switch.*_twc_control_enabled)

Master switch for the whole loop, default ON. When turned OFF, recompute_ct reports a constant 0A (max availability) on all 3 phases instead of computing anything live. TWC3's own live correlation check then distrusts that static value within seconds of a session starting and falls back to its own internal ceiling — i.e. it ends up ignoring this firmware entirely and charges at whatever it decides on its own (e.g. the Tesla app's own current slider). Useful for temporarily handing a session back to TWC3's stock behavior without touching the RS485 wiring or reflashing.

Before the first flash

  1. Copy secrets.yaml.examplesecrets.yaml (it's in .gitignore, never pushed) and fill in:
    • WiFi SSID/password, fallback AP password
    • API encryption key (python3 -c "import os,base64;print(base64.b64encode(os.urandom(32)).decode())")
    • OTA password
    • twc_breaker_limit_a — the value entered in the Tesla installer app's Home Load Management / CT clamps section for TWC3 — must match exactly, otherwise the limit will be offset. This is typically the physical branch breaker derated to 80% for continuous load (e.g. a 3x25A breaker → 20A here), not necessarily the breaker's own rating — use whatever value is actually configured on the TWC3 itself, not a recomputed one
    • main_breaker_limit_a — your main incomer breaker (measured by the Shelly Pro 3EM). Can be higher than twc_breaker_limit_a — the car is limited by whichever of the two is lower
    • ha_current_a_entity / ha_current_b_entity / ha_current_c_entity — your Shelly Pro 3EM's per-phase current entities in HA (Settings → Devices & Services → Shelly → the device's entities, or Developer Tools → States to find the exact IDs)
    • ha_power_a_entity / ha_power_b_entity / ha_power_c_entity — the matching per-phase signed active power entities (negative = export, positive = import)
    • ha_charge_from_grid_entity — the input_boolean helper you create in step 4 below (defaults to input_boolean.charge_from_grid)
    • twc_vitals_ip — TWC3's own LAN IP address (find it in your router's DHCP client list — TWC3 exposes an unauthenticated local /api/1/vitals JSON endpoint used for the R1 hard floor, the household-only self-balancing signal, and diagnostic sensors)
  2. The Shelly CT clamps must be on the main incomer (measuring the TWC branch too) — otherwise the formula in recompute_ct doesn't hold.
  3. In Home Assistant, confirm the 6 entities from step 1 exist and update with the Shelly's own refresh cadence — no further config needed, the firmware reads them directly by entity ID. This project's own Shelly is configured for Modbus polling at a 1s update interval in HA (instead of Shelly's default RPC-push integration, which updates every ~5-15s) — not a fix for a problem with the classic RPC integration, just tighter surplus-tracking precision on top of it; the classic RPC-based integration works fine too, just at coarser granularity (see TODO below).
  4. In Home Assistant, create the input_boolean helper referenced by ha_charge_from_grid_entity (Helpers → Toggle). If it doesn't exist, the firmware safely falls back to GRID mode.
  5. If your utility nets import/export across all 3 phases together for billing, enable switch.*_aggregate_balance_metering (default OFF) once FVE mode is confirmed working in plain per-phase mode first.

Physical wiring

  • RS485 A/B from the Waveshare board to TWC3's internal RS485 terminals (inside the enclosure, near mains voltage → have an electrician handle it / turn off the breaker before opening it).
  • Board pins: TX=GPIO17, RX=GPIO18, DE/RE (flow control)=GPIO21.
  • If TWC3 is at the end of the RS485 bus (typically point-to-point), enable the 120Ω termination jumper on the board.
  • Power the ESP32 independently (USB-C or 7-36V DC terminal) — the RS485 side is galvanically isolated from TWC3.

Build & flash

python3 -m venv venv
./venv/bin/pip install esphome
./venv/bin/esphome run twc-control.yaml   # first time over USB, then OTA (--device <host>.local)

Diagnostic entities in HA

  • sensor.*_twc_poll_interval, *_twc_time_since_last_poll, binary_sensor.*_twc_polling_active — tracks TWC3's real 0xF4 Modbus polls.
  • sensor.*_shelly_real_current_l1/l2/l3, *_shelly_active_power_l1/l2/l3 — real measured data mirrored in from HA (signed power: − export, + import).
  • sensor.*_twc_reported_current_l1/l2/l3 — what's currently being reported to TWC3.
  • binary_sensor.*_shelly_data_fresh — is the mirrored real-current/power data available (HA-reported, debounced — see Fail-safe above).
  • binary_sensor.*_twc_ha_link_ok — is the HA API connection active.
  • binary_sensor.*_charge_from_grid — currently mirrored mode from HA.
  • sensor.*_twc_vitals_current_l1/l2/l3, *_twc_vitals_vehicle_current — the car's own per-phase/total current, straight from TWC3's local vitals API (diagnostic; also feeds the R1 floor and the household-only signal).
  • binary_sensor.*_twc_vitals_contactor_closed — TWC3's own reported contactor state, from vitals.
  • switch.*_aggregate_balance_meteringdefault OFF, FVE-mode-only, see "aggregate/net balance metering" above.
  • switch.*_twc_control_enableddefault ON, see "Disabling external control" above.
  • number.*_fve_offset — manual kW offset added to the FVE-mode self-balancing target, runtime-adjustable in HA (-5.0..+5.0).
  • switch.*_zone_steering_mode, binary_sensor.*_zone_steering_engaged, and the number.*_zone_steering_* tuning entities — see "Zone steering" above.

Known limitations / behavior

  • Home Assistant is a hard dependency for power control, not just start/stop — if the HA API connection or the 6 mirrored real-current/power entities go stale, the firmware fails safe (reported = twc_breaker_limit_a, 0A available) rather than continuing to charge on old data. This trades away the earlier direct-HTTP-poll design's partial independence from HA in exchange for avoiding Shelly Gen2's brute-force login protection entirely (no local auth to manage at all). TWC3's own vitals API is polled directly (no HA dependency) but is used only as a diagnostic/ supporting signal, not as a substitute data source for fail-safe purposes.
  • TWC3 FW 26.26.1 does not proportionally track reported below its own configured breaker limit — confirmed live, repeatedly — and its reaction above the limit is not a sharp threshold but a time-integrated response that eventually reduces at any excess, reacting faster the further past the limit reported sits (see "TWC3 reaction curve" above for the full measured data). This is a firmware behavior, not something this project can compute around; the whole publication-law design (see "How it works" above) — and zone steering's discrete bands — exist to work with it rather than against it.
  • FVE mode is a bang-bang-flavored controller (not PID) — near signed≈0 (exactly balanced) it may pulse slightly around zero grid exchange, and the household-only self-balancing target is slew-rate-limited on the way down (desired_avail_slew_down_a_per_s, 1A/s), so it deliberately does not react instantly to a sudden load/export change in that direction — but recovers quickly (desired_avail_slew_up_a_per_s, 10A/s) once conditions improve.
  • The register map (identification block, Neurio meter MAC/model/serial number) is a fixed placeholder taken from the reverse-engineered project linked below — it's not real data from any physical device.

This project is a work in progress. Initial results are good, but more testing (more sessions, more weather/load conditions, longer runs) is still needed before treating any part of it — the classic publication law or zone steering — as fully settled.

TODO

  • Verify the actual impact of reverting to the original RPC-based Shelly update interval (~5-15s) vs. the current Modbus-polled 1s interval — quantify how much (if any) surplus-tracking precision is actually lost at the coarser cadence, since the classic RPC integration is simpler to set up and doesn't need Modbus configured on the Shelly.
  • Investigate removing Home Assistant as a hard dependency entirely: pulling current/power values directly from the Shelly (no HA in the data path for power control), plus a local web UI on the ESP32 itself for configuring the runtime-adjustable variables currently exposed only as HA number/switch entities.

Sources

License

MIT — chosen for compatibility with Klangen82/tesla-wall-connector-control (also MIT), the primary code source referenced above.

About

ESPHome firmware for ESP32-S3-RS485-CAN that controls Tesla Wall Connector 3 charging current locally via RS485 (Neurio/Generac meter emulation), driven by live Home Assistant data — solar self-balancing, dual-breaker protection, no cloud dependency for power control.