forked from sandialabs/Python-Automation-with-CymPy
-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathSingleNCO_ExampleScript.py
More file actions
587 lines (427 loc) · 23 KB
/
SingleNCO_ExampleScript.py
File metadata and controls
587 lines (427 loc) · 23 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
# -*- coding: utf-8 -*-
"""
BSD 3-Clause License
Copyright 2024 National Technology & Engineering Solutions of Sandia, LLC (NTESS). Under the terms of Contract DE-NA0003525 with NTESS, the U.S. Government retains certain rights in this software.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions are met:
* Redistributions of source code must retain the above copyright notice, this
list of conditions and the following disclaimer.
* Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation
and/or other materials provided with the distribution.
* Neither the name of the copyright holder nor the names of its
contributors may be used to endorse or promote products derived from
this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
@author: jazzoli & lblakel
This script authored by Joseph Azzolini, Logan Blakely, and Matthew J. Reno
at Sandia National Laboratories as part of DOE i2x funding
Contact: Joseph Azzolini - jazzoli@sandia.gov
Logan Blakely - lblakel@sandia.gov
Matthew J. Reno - mjreno@sandia.gov
"""
### Single Optimization Study Script ###
# This script runs a single network configuration optimization instance and
# reports the hosting capacity before and after the optimization
# The workflow is:
# 1. Load .sxst model using CymPy library
# 2. Run EPRI DRIVE to determine intial hosting capacity
# 3. Run Network Configuration Optimization Tool and adjust the model
# 4. Run EPRI DRIVE again to determine hosting capacity after the
# changes suggested by the NCO are applied
# The results of steps 2-4 are saved as .xlrd or .csv files
#%% Python Library Imports
import numpy as np
import pandas as pd
import cympy
import cympy.rm
import locale
#import xlrd
###############################################################################
#%% Set directory paths and filenames
# Location and name of .sxst file
studyFolderPath = r'C:\<Path>\<To>\<Study>\<Folder>'
studyFilename = r'\studyFile.sxst'
# Folder to save .xlrd and .csv results
saveResultsFolder = r'C:\<Path>\<To>\<Save\<Results>'
###############################################################################
#%% Open CYME Study and Verify that it loaded correctly
print('Opening CYME Study')
print('')
locale.setlocale(locale.LC_NUMERIC, '')
cympy.app.ActivateRefresh(True)
studyFilePath = studyFolderPath + studyFilename
cympy.study.Open(studyFilePath)
cympy.study.ActivateModifications(False)
# Check to see if the study loaded
spot_loads = cympy.study.ListDevices(cympy.enums.DeviceType.SpotLoad)
networks_df = pd.DataFrame(cympy.study.ListNetworks())
networks = cympy.study.ListNetworks() # This gives all 'networks' which may include transmission lines
feeders = cympy.study.ListNetworks(cympy.enums.NetworkType.Feeder) # This gives only 'networks' which are feeders which is what Drive requires
# Get load models and load characteristics for EPRI DRIVE settings
# In this example, custom load models were created for peak and light load conditions
# Those load models (index 4 and 5, respectively) were hard-coded in this example, since they are required inputs for EPRI DRIVE
# However, this code shows how you would access the various load models available in a CYME study
LoadModels = cympy.study.ListLoadModels()
LoadModelNames = []
LoadModelIDs = np.zeros((len(LoadModels),1),dtype=int)
for ii in range(len(LoadModels)):
LoadModelIDs[ii]=LoadModels[ii].ID
LoadModelNames.append(LoadModels[ii].Name)
peakLoadName = LoadModelNames[4]
peakLoadID = LoadModelIDs[4,0]
lightLoadName = LoadModelNames[5]
lightLoadID = LoadModelIDs[5,0]
feeders = cympy.study.ListNetworks(cympy.enums.NetworkType.Feeder)
###############################################################################
#%% Get Initial Switching Device State List
# The below includes Switch, Recloser, and Breaker
switchList = cympy.study.ListDevices(cympy.enums.DeviceType.Switch)
breakerList = cympy.study.ListDevices(cympy.enums.DeviceType.Breaker)
recloserList = cympy.study.ListDevices(cympy.enums.DeviceType.Recloser)
fuses = cympy.study.ListDevices(cympy.enums.DeviceType.Fuse)
switchingDeviceTypes = []
# From switch list, get a list of all switch ids
switchIDs = []
switchStatus = []
for switchCtr in range(0,len(switchList)):
currSwitch = switchList[switchCtr]
currID = currSwitch.GetValue('DeviceNumber')
#currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Switch)
currState = currSwitch.GetValue('ClosedPhase')
if currState == 'None':
currState = 'Open'
else:
currState = 'Close'
switchIDs.append(currID)
switchStatus.append(currState)
switchingDeviceTypes.append('Switch')
# From breaker list, get a list of all breaker ids
breakerIDs = []
breakerStatus = []
for breakerCtr in range(0,len(breakerList)):
currBreaker = breakerList[breakerCtr]
currID = currBreaker.GetValue('DeviceNumber')
#currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Breaker)
currState = currBreaker.GetValue('ClosedPhase')
if currState == 'None':
currState = 'Open'
else:
currState = 'Close'
breakerIDs.append(currID)
breakerStatus.append(currState)
switchingDeviceTypes.append('Breaker')
# From recloser list, get a list of all recloser ids and states
recloserIDs = []
recloserStatus = []
for recloserCtr in range(0,len(recloserList)):
currRecloser = recloserList[recloserCtr]
currID = currRecloser.GetValue('DeviceNumber')
#currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Recloser)
currState = currRecloser.GetValue('ClosedPhase')
if currState == 'None':
currState = 'Open'
else:
currState = 'Close'
recloserIDs.append(currID)
recloserStatus.append(currState)
switchingDeviceTypes.append('Recloser')
# Note: We chose to omit fuses from consideration, but those could be added with the same syntax,
# simply subsitute the keyword Fuse for Recloser
allSwitchingDeviceIDs = switchIDs + breakerIDs + recloserIDs
allSwitchingStates = switchStatus + breakerStatus + recloserStatus
# Write Switch states to csv
df = pd.DataFrame()
df['Switch ID'] = np.array(allSwitchingDeviceIDs)
df['Status'] = allSwitchingStates
df['Type'] = switchingDeviceTypes
filename = '\SwitchingDevicesStates_Initial.csv'
filePath = saveResultsFolder + filename
df.to_csv(filePath)
print('')
# Notes:
# Both of these methods will get the current status of a switching device
# currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Switch)
# currState = currSwitch.GetValue('ClosedPhase')
# currSwitch.GetValue('ClosedPhase') will return 'None' if the switch is open and
# 'ABC', 'A', 'B', 'C', 'AB', 'AC', 'BC' if closed, depending on the phases which
# The switching device is connected to. We converted this to open/close because
# it's a little easier to manually create a list of switch statuses without knowing
# all of the phase connections - for use in the SetSwitchesRunDrive_Script - since
# the phase information can be extracted from the device information. Directly
# saving the phase information may useful though
###############################################################################
#%% Set Up EPRI DRIVE Parameters
DRIVE = cympy.sim.EPRIDrive() # Assigns the specific simulation a variable name
cympy.Describe('EPRIDriveParameters') # prints the settable parameters for this tool/simulation
# Use DRIVE.SetValue and DRIVE.GetValue to set a new value and get the current value respectively
#Parameters/Future Resource Settings
DRIVE.SetValue(True,'IncludeExistingDER')
DRIVE.SetValue('Photovoltaic','DERType')
DRIVE.SetValue(True,'InverterBasedInterface')
DRIVE.SetValue(False,'ExcludeExistingViolations')
DRIVE.SetValue(10.0,'MinTolerance')
DRIVE.SetValue('WholeNetwork','LargeDERDistribution')
DRIVE.SetValue(False,'UniformDERDistribution')
DRIVE.SetValue('Remove','BadImpedanceAction')
DRIVE.SetValue(100.0,'PowerFactor')
DRIVE.SetValue(120.0,'FaultContribution')
DRIVE.SetValue(60.0,'MaxDEROutputChange')
DRIVE.SetValue(100.0,'MaxDEROutputChange_AbnormalVoltages')
DRIVE.SetValue(False,'UseLoadModels') ###########################################
DRIVE.SetValue(True,'SimulatePeakConditions')
DRIVE.SetValue(True,'SimulateOffPeakConditions')
#DRIVE.SetValue(int(peakLoadID),'PeakLoadModelID') #########################################
#DRIVE.SetValue(int(lightLoadID),'MinLoadModelID') ###########################################
# Verifications
DRIVE.SetValue(False,'VerifyPrimaryOverVoltageLoad')
DRIVE.SetValue(True,'VerifyPrimaryVoltageDeviationGen')
DRIVE.SetValue(False,'VerifyPrimaryUnderVoltageLoad')
DRIVE.SetValue(False,'VerifyPrimaryUnderVoltageGen')
DRIVE.SetValue(105.0,'OverVoltageLimit')
# DRIVE.SetValue(95.0,'UnderVoltageLimit')
DRIVE.SetValue(False,'VerifyPrimaryVoltageDeviationLoad')
DRIVE.SetValue(True,'VerifyPrimaryVoltageDeviationGen')
DRIVE.SetValue(True,'VerifyRegulatorVoltageDeviation')
DRIVE.SetValue(3.0,'MaxVoltageDeviation')
DRIVE.SetValue(50.0,'MaxRegulatorVoltageDeviation')
DRIVE.SetValue(10.0,'AllowableViolation_Thermal_Deviation')
DRIVE.SetValue(1.0,'AllowableViolation_AbnormalVoltage')
DRIVE.SetValue(False,'VerifyThermalLoadingLoad')
DRIVE.SetValue(True,'VerifyThermalLoadingGen')
DRIVE.SetValue(100.0,'ThermalLoadingDischarging')
DRIVE.SetValue(1.0,'ThermalLoadingMinRating')
#If not including protection
DRIVE.SetValue(False,'VerifyAdditionalElementFaultCurrent')
DRIVE.SetValue(False,'VerifySympatheticTrip')
DRIVE.SetValue(False,'VerifyProtectionReach')
DRIVE.SetValue(False,'VerifyUnintentionalIslanding')
DRIVE.SetValue(False,'VerifyReverseFlow')
DRIVE.SetValue(False,'VerifyOperationalFlexibility')
DRIVE.SetValue(False,'VerifyFlicker')
# # If including protection
# DRIVE.SetValue(True,'VerifyAdditionalElementFaultCurrent')
# DRIVE.SetValue(10.0,'MaxFaultCurrentDeviation')
# DRIVE.SetValue(True,'VerifySympatheticTrip')
# DRIVE.SetValue(150.0,'BreakerZeroSequenceCurrent')
# DRIVE.SetValue(True,'VerifyProtectionReach')
# DRIVE.SetValue(10.0,'MaxBreakerFaultCurrentDeviation')
# DRIVE.SetValue(False,'VerifyUnintentionalIslanding')
# DRIVE.SetValue(False,'VerifyReverseFlow')
# DRIVE.SetValue(False,'VerifyOperationalFlexibility')
# DRIVE.SetValue(True,'VerifyFlicker')
# DRIVE.SetValue(0.35,'FlickerPst')
# DRIVE.SetValue(0.75,'FlickerPowerChange')
# DRIVE.SetValue(0.2,'FlickerShapeFactor')
# DRIVE.SetValue(0.0256,'FlickerCurveValue')
#Options
DRIVE.SetValue(False,'VerifyVoltageUnbalanceLoad')
DRIVE.SetValue(False,'VerifyVoltageUnbalanceGen')
DRIVE.SetValue(False,'GlobalEditDER')
DRIVE.SetValue(True,'ConsiderGenForGenImpacts')
DRIVE.SetValue(False,'ConsiderGenForLoadImpacts')
DRIVE.SetValue(False,'ConsiderStorageChargingForGenImpacts')
DRIVE.SetValue(False,'ConsiderStorageChargingForLoadImpacts')
DRIVE.SetValue(False,'DeleteIntermediateFilesAfterCalculation')
# Reset the Maximum Large DER Penetration to 20MW for 23kV feeders
print('Initial value - MaxLargeDERPenetrationLowVoltage: ' + DRIVE.GetValue('MaxLargeDERPenetrationLowVoltage'))
print('')
DRIVE.SetValue(20000,'MaxLargeDERPenetrationLowVoltage')
###############################################################################
#%% Run DRIVE with intial switch settings
print('Starting EPRI DRIVE Run')
print('')
DRIVE.Run(feeders)
# Save EPRI DRIVE Report as .xlsx file
# Specify the name of the desired report - this will need to be in the list cympy.rm.ListReports()
report_name = 'Hosting Capacity Summary Report (Powered by EPRI DRIVE™)'
# Specify the type of report as MSExcel to produce a .xlsx file
report_type_save = cympy.enums.ReportModeType.MSExcel
# Note that the path here must include the filename as well as the folder path
hc1Filename = r'\HCReport_Initial.xlsx'
savePathHC = saveResultsFolder + hc1Filename
cympy.rm.Save(report_name, feeders, report_type_save,savePathHC)
# Load report and calculate average HC across all feeders
hcData = pd.read_excel(savePathHC,header=None)
maxDERValues_Dist = []
maxDERValues_Cent = []
for rowCtr in range(0,hcData.shape[0]):
currRow = hcData.loc[rowCtr,:]
index1 = np.where(np.array(currRow)=='Hosting Capacity')[0]
if len(index1) > 0:
valueDist = currRow.loc[3]
valueCent = currRow.loc[5]
maxDERValues_Dist.append(valueDist)
maxDERValues_Cent.append(valueCent)
maxDistAvg = np.round(np.mean(maxDERValues_Dist),decimals=2)
maxCentAvg = np.round(np.mean(maxDERValues_Cent),decimals=2)
print('Calulating the HC results from the output file of the intial run of EPRI DRIVE')
print('The Average Max Distributed DER Before Running Optimizer is ' + str(maxDistAvg))
print('The Average Max Centralized DER Before Running Optimizer is ' + str(maxCentAvg))
print('')
###############################################################################
#%% Run Network Configuration Optimization tool
nco = cympy.sim.NetworkConfigurationOptimization()
nco.GetObjType() # command give the string to use for this module in the Describe function
cympy.Describe('SOMParameters') # The Describe function provides the list of settable parameters for the specified module
# Print intial parameter values
print('Initial value - Objective: ' + nco.GetValue('Objective'))
print('Initial value - Method: ' + nco.GetValue('Method'))
print('Initial value - ObjectiveLosses: ' + nco.GetValue('ObjectiveLosses'))
print('Initial value - AcceleratedSearch: ' + nco.GetValue('AcceleratedSearch'))
print('Initial value - InstallNewSwitch: ' + nco.GetValue('InstallNewSwitch'))
print('Initial value - LoadFlowParamConfigID: ' + nco.GetValue('LoadFlowParamConfigID'))
print('Initial value - ExcludedDeviceType: ' + nco.GetValue('ExcludedDeviceType'))
print('Initial value - OperateRemotelyControlled: ' + nco.GetValue('OperateRemotelyControlled'))
print('Initial value - ExcludedDevices: ' + nco.GetValue('ExcludedDevices'))
print('Initial value - AllowInitialViolation: ' + nco.GetValue('AllowInitialViolation'))
print('Initial value - IgnoreTieInSameTopo: ' + nco.GetValue('IgnoreTieInSameTopo'))
print('Initial value - ObjectiveOperations: ' + nco.GetValue('ObjectiveOperations'))
print('Initial value - ObjectiveLoadBalancing: ' + nco.GetValue('ObjectiveLoadBalancing'))
print('Initial value - ObjectiveDistance: ' + nco.GetValue('ObjectiveDistance'))
print('Initial value - ObjectiveVoltageExceptions: ' + nco.GetValue('ObjectiveVoltageExceptions'))
print('Initial value - ObjectiveLosses: ' + nco.GetValue('ObjectiveLosses'))
print('Initial value - ObjectiveOverload: ' + nco.GetValue('ObjectiveOverload'))
print('Initial value - ObjectiveWeightOperations: ' + nco.GetValue('ObjectiveWeightOperations'))
print('Initial value - ObjectiveWeightLoadBalancing: ' + nco.GetValue('ObjectiveWeightLoadBalancing'))
print('Initial value - ObjectiveWeightDistance: ' + nco.GetValue('ObjectiveWeightDistance'))
print('Initial value - ObjectiveWeightLosses: ' + nco.GetValue('ObjectiveWeightLosses'))
print('Initial value - ObjectiveWeightVoltageExceptions: ' + nco.GetValue('ObjectiveWeightVoltageExceptions'))
print('Initial value - ObjectiveWeightOverload: ' + nco.GetValue('ObjectiveWeightOverload'))
print('Initial value - EnableMinimumLoss: ' + nco.GetValue('EnableMinimumLoss'))
print('Initial value - MinimumLoss: ' + nco.GetValue('MinimumLoss'))
print('Initial value - EnableMinimumLoadingUnbalance: ' + nco.GetValue('EnableMinimumLoadingUnbalance'))
print('Initial value - MinimumLoadingUnbalance: ' + nco.GetValue('MinimumLoadingUnbalance'))
print('Initial value - EnableMinimumLengthUnbalance: ' + nco.GetValue('EnableMinimumLengthUnbalance'))
print('Initial value - MinimumLengthUnbalance: ' + nco.GetValue('MinimumLengthUnbalance'))
print('Initial value - EnableMinDistanceBetweenNewSwitch: ' + nco.GetValue('EnableMinDistanceBetweenNewSwitch'))
print('Initial value - MinDistanceBetweenNewSwitch: ' + nco.GetValue('MinDistanceBetweenNewSwitch'))
print('Initial value - EnableMaximumNumberSwitchingOperations: ' + nco.GetValue('EnableMaximumNumberSwitchingOperations'))
print('Initial value - MaximumNumberSwitchingOperations: ' + nco.GetValue('MaximumNumberSwitchingOperations'))
objectiveList = ['MinimizeLosses', 'MinimizeVoltageExceptions','MinimizeOverloadExceptions','BalanceLoad']
methodList = ['HeuristicLocal','HeuristicZones','HeuristicZones','HeuristicLocal']
nco.SetValue('MinimizeVoltageExceptions', 'Objective')
nco.SetValue('Iterative','Method')
# This tool takes the full list of networks including transmission lines
print('Run Network Configuration Optimization Tool')
print('')
print(networks)
nco.Run(networks)
# Save .xlsx report with NCO tool results
report_name = 'Network Configuration Optimization - Summary'
report_type_save = cympy.enums.ReportModeType.MSExcel
report_type_show = cympy.enums.ReportModeType.CYMESpreadsheet
filenameOpt = r'OptReport.xlsx'
savePathOpt = saveResultsFolder + filename
cympy.rm.Save(report_name, networks, report_type_save,savePathOpt)
# Using the list of ids, get the current/active switch state
switchStatusAfter = []
for switchCtr in range(0,len(switchList)):
currSwitch = switchList[switchCtr]
currID = currSwitch.GetValue('DeviceNumber')
currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Switch)
switchStatusAfter.append(currState)
# From breaker list, get a list of all breaker ids
for breakerCtr in range(0,len(breakerList)):
currBreaker = breakerList[breakerCtr]
currID = currBreaker.GetValue('DeviceNumber')
currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Breaker)
switchStatusAfter.append(currState)
# From recloser list, get a list of all recloser ids and states
recloserIDs = []
recloserStatus = []
for recloserCtr in range(0,len(recloserList)):
currRecloser = recloserList[recloserCtr]
currID = currRecloser.GetValue('DeviceNumber')
currState = cympy.study.QueryInfoDevice("EqState",currID,cympy.enums.DeviceType.Recloser)
switchStatusAfter.append(currState)
# Write Switch states to csv
df = pd.DataFrame()
df['Switch ID'] = np.array(allSwitchingDeviceIDs)
df['Status'] = switchStatusAfter
df['Type'] = switchingDeviceTypes
filenameSwitchAfter = '\SwitchingDeviceStates_AfterOpt.csv'
filePathSwitchAfter = saveResultsFolder + filenameSwitchAfter
df.to_csv(filePathSwitchAfter)
# Write before and after Switch states to csv
df = pd.DataFrame()
df['Switch ID'] = np.array(allSwitchingDeviceIDs)
df['Status Initial'] = allSwitchingStates
df['Status After NCO'] = switchStatusAfter
df['Type'] = switchingDeviceTypes
filenameSwitchBA = '\SwitchingStates_BeforeAfter.csv'
filePathOptBoth = saveResultsFolder + filenameSwitchBA
df.to_csv(filePathOptBoth)
###############################################################################
#%% Run EPRI Drive Again
print('Run EPRI DRIVE with new switch configuration')
print('')
DRIVE.Run(feeders)
# Reporting
report_name = 'Hosting Capacity Summary Report (Powered by EPRI DRIVE™)'
report_type_save = cympy.enums.ReportModeType.MSExcel
report_type_show = cympy.enums.ReportModeType.CYMESpreadsheet
filenameHC2 = r'\HCreport_AfterOpt.xlsx'
filePathHC2 = saveResultsFolder + filenameHC2
cympy.rm.Save(report_name, feeders, report_type_save,filePathHC2)
# Load report
hcData2 = pd.read_excel(filePathHC2,header=None)
maxDERValues_Dist2 = []
maxDERValues_Cent2 = []
for rowCtr in range(0,hcData2.shape[0]):
currRow = hcData2.loc[rowCtr,:]
index1 = np.where(np.array(currRow)=='Hosting Capacity')[0]
if len(index1) > 0:
valueDist = currRow.loc[3]
valueCent = currRow.loc[5]
maxDERValues_Dist2.append(valueDist)
maxDERValues_Cent2.append(valueCent)
maxDistAvg2 = np.round(np.mean(maxDERValues_Dist2),decimals=2)
maxCentAvg2 = np.round(np.mean(maxDERValues_Cent2),decimals=2)
print('Calulating the HC results from the output file of the second run of EPRI DRIVE')
print('The Average Max Distributed DER After Running Optimizer is ' + str(maxDistAvg2))
print('The Average Max Centralized DER After Running Optimizer is ' + str(maxCentAvg2))
print('')
print('')
###############################################################################
#%% OPTIONAL SECTION
# This section is not required for the main script functionality above, these
# scripts are provided as examples of additonal cympy functionality for future
# work
# Print a list of devices in the system - OPTIONAL to demo additional functionality
devices = cympy.study.ListDevices()
for ctr in range(0,len(devices)):
print(devices[ctr])
# This is an alternative method to get the list of switches and provides an
# example of searching the full list of devices for particular device types
# Search the full list of devices for devices with the integer type of switch which is 6
# This could be used for any type of device in the study
typeValue = 6 # This is the integer designator for switches
switchList = []
for ctr in range(0,len(devices)):
currDevice = devices[ctr]
if currDevice.DeviceType == typeValue:
print(currDevice)
switchList.append(currDevice)
switch0=switchList[0]
switch0.GetObjType() #This gives you the string for this type of device to use in the Describe command below
cympy.Describe('Switch') # prints the settable parameters for this tool/simulation
switch0.GetValue('NormalStatus')
switch0.GetValue('DeviceNumber')
switch0.GetValue('DeviceStage')
switch0.GetValue('ConnectionStatus')
switch0.GetValue('Flags')
switch0.GetValue('ClosedPhase')
# To save out a new study after making changes
newStudyFilename = '\\newStudy2.sxst'
studyFilePath = saveResultsFolder + newStudyFilename
cympy.study.Save(studyFilePath,True,True,True)