using System.IO;
using System.Windows;
using ArIED61850Tester.Models.IoTesting;
using ArIED61850Tester.Services.IoTesting;
using Microsoft.Win32;
namespace ArIED61850Tester;
public partial class IoListTestingWindow
{
private async void AddFatIedFromScl_Click(object sender, RoutedEventArgs e)
{
if (!CanAddFatIed || Owner is not MainWindow engineeringWindow)
return;
var dialog = new OpenFileDialog
{
Title = "Add IEC 61850 IED to current FAT workspace",
Filter = "IEC 61850 SCL (*.scd;*.cid;*.icd;*.iid;*.ssd)|*.scd;*.cid;*.icd;*.iid;*.ssd|XML SCL (*.xml)|*.xml|All files (*.*)|*.*",
CheckFileExists = true,
Multiselect = true
};
if (dialog.ShowDialog(this) != true)
return;
var result = await ImportAdditionalSclSourcesAsync(engineeringWindow, dialog.FileNames);
if (!result.Succeeded)
ShowActionResult(result, "IED could not be added");
}
internal async Task<IoTestSessionActionResult> ImportAdditionalSclSourcesAsync(
MainWindow engineeringWindow,
IReadOnlyCollection<string> sclPaths)
{
ArgumentNullException.ThrowIfNull(engineeringWindow);
ArgumentNullException.ThrowIfNull(sclPaths);
if (_isAddingFatIeds)
return IoTestSessionActionResult.Failure("Another SCL append is already being prepared for this FAT workspace.");
SetAddingFatIeds(true);
PreparationStatusText = $"Importing {sclPaths.Count} SCL source(s) into the current FAT workspace…";
try
{
var result = await engineeringWindow.AppendSclIedsToLoadedFatAsync(this, sclPaths);
PreparationStatusText = result.Message;
return result;
}
catch (OperationCanceledException)
{
const string message = "SCL append was cancelled.";
PreparationStatusText = message;
return IoTestSessionActionResult.Failure(message);
}
catch (Exception ex) when (ex is IOException or UnauthorizedAccessException or InvalidDataException or InvalidOperationException or ArgumentException)
{
PreparationStatusText = ex.Message;
return IoTestSessionActionResult.Failure(ex.Message);
}
finally
{
SetAddingFatIeds(false);
}
}
internal void RegisterAddedIeds(IReadOnlyCollection<Models.IoTesting.IoTestIedPlan> addedIeds)
{
Project.InitializeRuntimeNotifications();
foreach (var ied in addedIeds)
{
if (_selectedIedContextInstalled)
ied.PropertyChanged += ContextIed_PropertyChanged;
Storage?.TrackAddedIed(ied);
}
FatIedList.Items.Refresh();
SelectedIed = addedIeds.FirstOrDefault() ?? SelectedIed;
Raise(nameof(ProjectSummary));
RaiseStatusProperties();
RaiseSelectedIedContextProperties();
Storage?.ScheduleSave();
}
}