Capturing this discussion from #3:

As a side note, the power handling increase going from the AO3400A to AON7400A is probably lost due to the SS54 diode on the power input being limited to 5A. Using another AON7400A could be suitable for reverse polarity protection instead of the diode. BOM cost increase would be fairly small since the extended part cost of the AON7400A is already done by using it once.